About Pharmaceutical industry Filter Cartridges Dia 115 mm with Thread
APPLICATIONS
ADVANTAGES
Easy and quick installation by screwing into filter holder
No tools required
Filter medium customized to application
Star-shaped bottom design
FILTER MEDIA OPTIONS
(Customized to application)
POSSIBLE EQUIPMENTS / TREATMENTS
Antistatic
Oil and water repellent
Microporous finish
Nano fibres
ePTFE membrane
Certification:
FEATURES
Max operating temperature: 80C
Metal parts: Galvanized steel
Cleanable by compressed air
SPECIAL TYPES AVAILABLE
Temperature resistant up to 220C
Suitable for ATEX applications (all zones)
Certified for food production (EC + US FDA)
Stainless steel metal parts
Custom solutions available
ACCESSORIES
Filter holders
Solenoid valves
Valve control systems
INSTALLATION TYPES & DIMENSIONS
A. Raw Gas Side Installation Thread Rd 60
Dimensions:
115
100
Inner 72
Length: L (varies)
Filter holder
Hole in plate
B. Raw Gas Side Installation Thread Rd 72
Dimensions:
115
100
Inner 80
Length: L
Filter holder
Hole in plate
C. Raw Gas Side Installation Thread Rd 74
Dimensions:
TECHNICAL DATA (Length & Filter Area)
Thread Rd 60 Accessory: Filter Holder 310-001-000043
(mm) | Length L (mm) | Filter Area (m) |
|---|
115 | 202 | 0.3 |
115 | 302 | 0.4 |
115 | 602 | 0.8 |
115 | 982 | 1.3 |
115 | 1202 | 1.6 |
Thread Rd 72 Accessory: Filter Holder 310-001-000071
(mm) | Length L (mm) | Filter Area (m) |
|---|
115 | 202 | 0.3 |
115 | 302 | 0.5 |
115 | 602 | 1.0 |
115 | 982 | 1.6 |
115 | 1202 | 2.0 |
Thread Rd 74 Accessory: Filter Holder 310-001-000045
(mm) | Length L (mm) | Filter Area (m) |
|---|
115 | 202 | 0.3 |
115 | 302 | 0.5 |
115 | 602 | 1.0 |
115 | 982 | 1.6 |
115 | 1202 | 1.9 |
Get the ultimate in-demand Pharmaceutical Industry Filter Cartridges Dia 115 mm with Thread-engineered for first-class performance and reliability. Featuring a sterling cylindrical, pleated design for high surface area, these filter cartridges deliver remarkable filtration efficiency (up to 99.98%) and dirt-holding capacity. Available in 10, 20, 30, and 40 inch lengths, with customizable options on request, the threaded interface allows for easy installation and replacement. Constructed using premium materials like Polypropylene, Stainless Steel, and PTFE, they withstand temperatures up to 95C and pressures up to 6 Bar. Perfect for sterile liquid and gas filtration, these cartridges are autoclavable and compatible with a wide range of chemicals, making them a premier choice for pharmaceutical manufacturing. Apply for a competitive quotation or request a markdown for bulk orders from the trusted exporter, manufacturer, and supplier in India.
Versatile Usage & Applications in Pharmaceuticals
Pharmaceutical industry Filter Cartridges Dia 115 mm with Thread are designed for sterile and fine filtration in both liquid and gas applications, ensuring pure, contaminant-free products. Ideal for use in manufacturing, formulation, and laboratory settings, these filter cartridges suit a wide array of processing needs. Their robust construction and high surface pleated design facilitate first-class filtration performance on a variety of surfaces, making them indispensable for pharmaceutical manufacturers seeking stringent quality standards.
Packaging, Supply Ability, and Sampling Details
Shipped goods are securely packaged to maintain filter sterility and quality during transit. With a vast supply ability, we fulfill both large and small orders efficiently. Customers can request a sample before placing bulk orders to ensure suitability for their applications. Our prompt drop-off services and detailed quotations guarantee seamless procurement. Rely on our streamlined logistics for timely delivery, whether local or international, ensuring you get the right filter cartridge quickly and reliably.
FAQ's of Pharmaceutical industry Filter Cartridges Dia 115 mm with Thread:
Q: How do I choose the correct Pharmaceutical industry Filter Cartridge size for my process?
A: Select your filter cartridge based on required micron rating, media type, and length (10, 20, 30, or 40 inches). Consider the chemical compatibility and filtration capacity needed for your application.
Q: What sterilization methods are suitable for these filter cartridges?
A: These cartridges are autoclavable and can undergo steam sterilization, making them highly suitable for pharmaceutical and sterile processing environments.
Q: When should the filter cartridge be replaced?
A: Replace the cartridge when you notice a significant drop in flow rate or increase in pressure differential across the filter system, indicating particle accumulation. The long service life aids in reducing frequent change-outs.
Q: Where are these filter cartridges primarily used within the pharmaceutical industry?
A: They are extensively used in manufacturing, formulation, and laboratory environments for sterile liquid and gas filtration processes, ensuring safety and product purity.
Q: What are the key benefits of using pleated filter cartridges with threaded ends?
A: Pleated design provides high surface area for greater filtration capacity, and the threaded ends ensure easy installation and replacement, minimizing downtime and maintenance.
Technical Details 